Those pictures are realy nice to understand. But still than, I am not shure, if there is possible to have from one shop 1RW from shop to safe corridor for about 35m and then into the staricase. For thi corridor I think, that it is not permited to have it like normal ´notwendier flur´.
We build such big center in Slovenia.
In our country we can use almost all world guidelines. So we can choose IBC, NFPA, MBO, TRVB, VKF, etc...
According to local laws we can not plan this buidling, also according to VKVO is very hard to plan it (I think).
First I have to find solution at myself and then I go to the authority. So, I have to check, which guidelines are for me the best.
NFPA are good, there is only a problem, because it demands 2 or 3 hours fire resistance. Then you have UL (unlimited) fire compartments. That is good for me because of such big center. Problem with 2-3 hour is that, if you want to use prefabricated panels, you can get normaly (form normal price) 90 minutes. You can put a fire protection (Promat) on all the walls, but also this is wery expensive.